Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13668590

- Product Categories
- Friendly Links
Information Name: | Fuel (gas) oil furnace |
Published: | 2015-03-12 |
Validity: | 30 |
Specifications: | |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Structure description: organic heat carrier furnace is a new type of special boilers, also known as oil furnace, with a low-pressure, high-temperature operating characteristics, the heating temperature can reach 340 ℃ liquid or vapor phase 400 ℃ degrees. Those who need to be heated uniformly stable, and does not allow direct flame heating process heating temperature at 150 ℃ -380 ℃ between the various production applications can be used in both organic heat carrier heating. Fuel (gas) organic heat carrier furnace oil (gas) as fuel to oil as the medium, using hot oil circulation pump to force the liquid circulating medium, the heat supplied to the heating equipment and then return to oven to reheat, with to obtain high operating temperatures at low pressures, and can be run on the high-precision control of the media work. System thermal efficiency is high, due to the overall module installation, easy operation and maintenance, is a safe, efficient, energy-saving heating equipment the ideal choice. Fuel (gas) to form a radiation heating coil inner surface by high temperature flame burner ignition generated after entering through the rear of the forward rotation of the inner coil 180 ° into the inner and outer tube mezzanine area of ??convection heating surface. Then enter in the upper mezzanine, the second mezzanine area outside the coil, the second mezzanine area in the rear of the chimney into the atmosphere. Features: (1) to obtain the low-pressure high-temperature thermal medium, easy to adjust, heating uniformity, to meet the precise process temperature. (2), liquid circulation heat, no condensation heat loss emissions, high thermal efficiency of the heating system. (3), the working medium heat and heat and temperature changes in the volume of movements, there is compensation measures within the system. (4), before the heating cycle has strict control of technical measures in the medium of air, water and other low volatile matter content. Control System Description: This organic heat carrier furnace, more advanced program control from normal combustion to achieve various functions necessary for energy in the normal state, the state of the accident and extraordinary circumstances, the implementation of conservation automatic alarm, with appropriate level controllers, pressure controllers, temperature controllers, import and export pressure indicator, temperature indicator of import and export, to ensure heat carrier temperature fluctuations within the normal range, the pressure within the allowable range of pressure fluctuations. Model parameters Rated power KW / h maximum design pressure Mpa ℃ thermal efficiency% export diesel oil consumption kg / h of gas consumption m3 / h circulating volume m3 / h furnace oil content m3 Weight T Dimensions (mm) diameter height YYL -120YC 120 0.9 340 93 10.83 12.90 12.5 0.14 1800 1150 1350 YYL-230YC 230 20.75 24.73 20 0.27 2500 1250 1900 YYL-350YC 350 31.58 37.63 30 0.41 3300 1400 2300 YYL-470YC 470 42.40 43.71 40 0.55 4000 1600 2500 YYL-700YC 700 63.16 75.26 50 0.82 4450 1650 3000 YYL-930YC 930 83.92 100 80 1.10 4800 1700 3500 YYL-1200YC 1200 108.28 129.03 94 1.37 5650 1850 4000 Horizontal :( burning heavy oil, light oil, combustible gas) heat carrier furnace model parameters Rated Power KW / h maximum design pressure Mpa ℃ thermal efficiency% export diesel oil consumption kg / h of gas consumption m3 / h circulating volume m3 / h furnace oil content m3 Weight T Dimensions (mm) length and breadth YYW-120YC 120 0.9 340 93 10.83 12.90 12.5 0.14 1950 1500 1150 1350 YYW-230YC 230 20.75 24.73 20 0.27 2630 2000 1250 1450 YYW-350YC 350 31.58 37.63 30 0.41 3520 2500 1300 1600 YYW-470YC 470 42.40 43.71 40 0.55 4200 3200 1450 1700 YYW- 700YC 700 63.16 75.26 50 0.82 4600 3500 1505 1760 YYW-930YC 930 83.92 100 80 1.10 5100 3600 1700 2000 YYW-1200YC 1200 108.28 129.03 94 1.37 5900 3850 1800 2160 YYW-1500YC 1500 135.35 161.29 100 1.78 6800 4350 1900 2280 YYW-1800YC 1800 162.42 193.50 150 2.06 9000 4800 2000 2500 YYW-2300YC 2300 207.54 247.31 170 2.60 10500 5300 2200 2700 YYW-2900YC 2900 261.68 311.82 200 3.97 12750 5500 2400 3000 YYW-3500YC 3500 315.82 376.34 313 4.11 18500 5800 2500 3100 YYW-4100YC 4100 369.96 440.86 350 4.79 20800 6300 2600 3200 YYW-4700YC 4700 424.10 505.37 400 5.45 23500 6500 2800 3400 YYW-5800YC 5800 523.36 623.66 500 6.75 28600 7300 3000 3600 YYW-7000YC 7000 631.65 752.69 500 8.22 35500 7700 3200 3800 Henan Tai Boiler Group Co. YYW Product Configuration Checklist Page 1 of 1 drawing number or model number Product Unit origin a host organic heat carrier furnace 1 YYW organic heat carrier furnace Our two main units supporting auxiliary 1 RY hot oil circulating pump station Qingdao 2 2CY injection pump station Qingdao 3 plant expansion tank station elevation digit factory four low oil reservoir Taiwan factory standard factory 5 DN oil separator station Nanjing 6 DN Y-type filter sets Nanjing 7 diameter: ¢ 273 meters from the factory chimneys 8 months Zhengzhou Yuming shutoff valve shut-off valve 9 Yu-Ming 10 months Zhengzhou Zhengzhou Yuming ball a shut-off valve 11 a station in Nanjing, Zhengzhou 12 cabinet Ronny 13 BT burner Italian Decker 14 thermocouple thermocouple wire purchased a 15-meter Shanghai Shanghai 16 gauges block Zhengzhou Yuming 17 pairs of metal thermometer a 18 gauge months Xinxiang Xinxiang 19 GB 20 GB nut bolt a Jiangsu Jiangsu three months factory data a total organic heat carrier furnace parts of random data in Figure 2 and 3 parts quality certificate supervisory inspection certificate 4 parts organic heat flow chart 5 parts carrier furnace body diagram in Figure 6 parts valve instrument 7 parts strength calculation summary table parts |
Admin>>>
You are the 7312 visitor
Copyright © GuangDong ICP No. 10089450, Tai Boiler Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7312 visitor
Copyright © GuangDong ICP No. 10089450, Tai Boiler Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility