Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13668590

- Product Categories
- Friendly Links
Information Name: | DZL- Horizontal Automatic chain steam boiler |
Published: | 2015-03-12 |
Validity: | 30 |
Specifications: | |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | DZL type chain grate boiler is a horizontal three-pass fire tube boiler mixed, arranged in a bouquet of threaded pipe drum. The left and right sides of the furnace tube equipped with a light water-cooled wall. Using light chain grate stoker achieve with blower, Fan mechanical ventilation, and air-scraper slag machine automatic slag. The furnace arch around the use of new energy-saving technologies furnace arch. Fuel from coal bucket fell on the grate into the combustion chamber, the flame is refracted through the arch upward through the body off to the side room to burn out before the smoke box, and then turn back from the pot before the smoke box control, and after the adoption of the smoke box into the economizer, then evacuating the draft fan to the chimney through the flue to the atmosphere. Features: 1. Horizontal Packaged Boiler type of fire tube boilers, natural cycle working fluid. The boiler heat exchange system by the drum, left header, water wall, which mainly have the furnace water wall heating surface, convection tube inside the drum and the drum section. When the product manufactured by the five major components: the main boiler, smoke duct, precipitators, piping systems. Of which the first four parts have been manufactured in the factory is completed, transportation to the installation site can be assembled, can greatly shorten the installation cycle, and can be installed to ensure product quality. 2. Advanced Design Features: The main boiler heating surface in a 20 # low pressure boiler seamless steel tubes made of boiler drum using special steel. About collection box is made of seamless steel pipe. 3. The use of refractory concrete arch furnace boiler pound crafted. After the arch is low and long, and therefore good combustion, flue wings and side wall using sintered refractory bricks. Boiler front wall, back wall using a common firebrick. 4. Grate with the wind and reasonable, the larger chamber, coal applicability. Adapt to all types of bituminous coal or anthracite coal mixed. Combustion. Due to the high temperature flue gas first enters the settling chamber, and then from both sides of the flue into the wings, before the smoke box, so good smoke and dust effects. 5. The water cycle is simple, reasonable structure and pressure parts, to ensure the quality of the situation, can operate safely. 6. combustion equipment for quick grate combustion equipment installed in the factory, manufacturing, transportation mounted directly on the ground you can post to the site. With a reasonable structure, compact, low consumption of steel, the boiler performance, weight, size and structure of the domestic product, compared with the capacity it has obvious advantages. Boiler work process: a substantially uniform particles by automatic stoker coal investment falls within the coal bucket, arch preheating zone before entering in the rotation of the chain grate. After falling into the slag pool fire burn area. High temperature flue gas generated by the combustion chamber by arch opening into the furnace flue at the lower rear of the wings, and then by the two wings of the flue heat, smoke box before flowing forward, enter into the convection heat transfer tubes Sheng Mei from the rear drum , dust collector, induced draft fan fed through the chimney into the atmosphere. Boiler feed water from the boiler feed pump is completed, demineralized water supply from the economizer, and then enter the drum, and then by the drop tube into the left header. Both sides of the Wall endothermic vaporization produces steam, steam into the drum separator, separated into the required heat flow from the main steam valve. Boiler model DZL1-0.7 (1.25) -AⅡ DZL2-0.7 (1.25) -AⅡ DZL4-1.25-AⅡ DZL6-1.25-AⅡ DZL8-1.25-AⅡ DZL10-1.25-AⅡ Rated evaporation t / h 1 2 4 6 8 10 rated working pressure MPa 0.7 (1.25) 0.7 (1.25) 1.25 1.25 1.25 1.25 Rated steam temperature ℃ 171 (194) 171 (194) 194 194 194 194 Rated water temperature ℃ 20 20 20 20 20 20 Reference heated area m2 39.5 76.12 135.98 226.72 396.26 412.3 grate area m2 2.65 3.74 4.3 7.22 10.3 11.8 Fuel AⅡ class design class bituminous coal bituminous AⅡ bituminous AⅡ AⅡ class class class bituminous coal bituminous AⅡ AⅡ class bituminous thermal efficiency 77.16% 77,788,181 79.6 Fuel consumption kg / h 155 311 615 888 11,851,507 emission concentration mg / Nm3 <80 <80 <80 <80 <80 <80 black smoke Ringelmann grade ≤1 ≤1 ≤1 grade grade grade ≤1 ≤1 ≤1 grade level Dimensions Length m × width m × height m 4.12 × 1.92 × 3.25 5.6 × 2.6 × 3.32 6.78 × 2.73 × 3.25 6.92 × 2.83 × 3.72 7.56 × 3.28 × 4.25 9.5 × 3.35 × 4.9 Boiler Weight t 11.35 22.73 27.26 38.13 54.26 57.63 DNmm 50 caliber main steam valve 80100150150150 feed valve bore DNmm 32 40 40 40 40 50 valve bore DNmm 2 × 40 2 × 50 2 × 50 2 × 80 2 × 80 2 × 80 drain valve bore DNmm 40 40,50 40,50 40, 50 40, 50 40, 50 gauge caliber DNmm 25 25 25 25 25 25 ° T4-72-11NO3.6A blower models T4-72-12NO3.3A right right right ° T4-72-11NO4.6A ° T4-72 -12NO6.4A ° T4-72-12NO7.0A right right right ° ° T4-72-12NO8.5A pressure 1260 1350 1,580,185,021,652,538 1,768,385,058,908,300 wind motor power 11258 13852 5.5 7.5 1115 1.5 3 spindle speed 2900r / min 2900r / min 2900r / min 2900r / min 1470r / min 1470r / min induced draft fan model Y5-48NO4.5C Y5-48NO5C Y5-48NO6C Y6-41-11 NO9C Y6-41-11 N10C Y6-41-11 N11C wind Pressure 2750 3084 3,215,349,035,343,623 wind 4200715611250 245,822,950,035,500 motor power 4 7.5 15 18.5 37 45 spindle speed 2800r / min 2800r / min 2800r / min 1750r / min 1750r / min 1480r / min to pump model 1.5GC5 × 4 1.5 GC5 × 7 1.5GC6 × 7 2GC5 × 7 2GC6 × 7 2GC6 × 7 flow 4.2m3 / h 6m3 / h 7.5m3 / h 7.5m3 / h 15m3 / h 15m3 / h Head 165 165,165,165,224,224 speed 2900r / min 2900r / min 2900r / min 2900r / min 2900r / min 2900r / min Motor power 5.5KW 7.5KW 7.5KW 11KW 22KW 22KW governor model GL1T GL2T GL4T GL6T GL8T GL10 shaft torque 2000NM 3000NM 5000NM 8000NM 9000NM 10000NM motor power 0.55KW 0.55KW 0.55 KW 0.75KW 1.1KW 1.1KW slag Model GBC-1B GBC-2B GBC-4B GBC-6B GBC-8B GBC-10B slag volume 800kg 1000kg 1500kg 1500kg 2000kg 2000kg motor power 0.75KW 1.1KW 1.1KW 1.1KW 1.5 KW 1.5KW on coal Model SMJ-1 SMJ-2 SMJ-4 SMJ-6 SMJ-8 SMJ-10 coal bucket capacity 0.13m3 0.16 0.19 0.23 0.27 0.38 Motor Power 1.1KW 1.1KW 1.1KW 1.1KW 1.1KW 1.1KW Dust Model CCQ-1 CCQ-2 CCQ-4 CCQ-6 CCQ-8 CCQ-10 distribution cabinet model DKG-1 DKG-2 DKG-4 DKG-6 DKG-8 DKG-10 Henan Tai Boiler Group Co. DZL product configuration list on the first page a total figure number or model number Product Name Origin 1 YCW host a boiler factory boiler hosts 24-72 Xinxiang low noise fan blower 3 Y10 Xinxiang draft fan low noise fan 41 (1/2 ) G boiler feed pumps Xinxiang Pump 5 YCW 6 YCW factory chimney smoke duct factory 7 YCW escalator factory 8 YCW 9 automatic water filter factory Fleck 10 US coal slag Changzhou Changzhou 11 12 governor Qingdao factory slowdown after 13 minutes cylinder 14 cabinet factory in Nanjing Ronny North Xinxiang chain grate grate 15 16 YCW 90 17 YCW elbow factory outlet of the induced draft fan 18 YCW take over the factory smoke box factory takeover two valves, instrumentation gauges Yuming 1 Y 2 X14W three cocks factory gauges 3 YCW & nbs, p; 4 A48H factory gauges water trap valve spring full-Kai Yu Ming Zhengzhou valve 5 J41H main steam valve (main steam valve) Zhengzhou-Ming valve 6 J41H shutoff valve (Vice steam valve) Zhengzhou-Ming valve 7 J41H shutoff valve (to valve) Zhengzhou-Ming valve 8 H41H check Zhengzhou 9 Q41F ball Zhengzhou 10 P48H drain valve Zhengzhou 11 P48H drain valve Zhengzhou 14 X49X Xinxiang flat color level gauge water level electrode 15 SZB level controller Ying Yang Zhengzhou bolt 16 GB 17 GB 18 GB bolt nut Zhengzhou Zhengzhou Zhengzhou nut 19 GB 20 customers Linyi three optional auxiliary economizer design technology for the user a list of documents safety valve emissions calculations installation manual supplied 2 3 Product quality certificate 4 boiler product safety and quality supervision and inspection certificate 5 overall layout of the main auxiliary boiler boiler total 6 7 8 boiler piping, instrumentation valves 9 boiler foundation |
Admin>>>
You are the 7312 visitor
Copyright © GuangDong ICP No. 10089450, Tai Boiler Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 7312 visitor
Copyright © GuangDong ICP No. 10089450, Tai Boiler Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility